Panels that are empty on purpose

Empty is not broken.

Anything on Chassis & Power, without a BMC. The evaluation appliance is a
virtual machine with no IPMI, so the whole dashboard reads DOWN / No data.
That is the correct result, not a failed install. On physical hardware whose BMC
is reachable only over the network rather than in-band, these series can also
stay empty while the console's own hardware page works.

Chassis & Power on a virtual machine — no BMC, so nothing to report

Fans, voltage, current and power, on a DC-fed chassis with no PSU
sub-sensors. That row ships collapsed so a chassis without them shows nothing
rather than four empty axes, and expands into real graphs on a chassis that has
them.

Any labelled counter before its first increment. QoS, webhook and login
counters have no series at all until something increments them. A quiet box
shows nothing here; a busy one fills in within a scrape or two.